The China Mail - France's City of Light switches to climate-resilient power cables

USD -
AED 3.672503
AFN 63.999633
ALL 81.13116
AMD 364.066319
ANG 1.790365
AOA 917.999554
ARS 1524.997501
AUD 1.439429
AWG 1.8025
AZN 1.699887
BAM 1.725719
BBD 2.018882
BDT 123.247965
BGN 1.683441
BHD 0.377906
BIF 3005.722202
BMD 1
BND 1.279885
BOB 12.063778
BRL 5.184055
BSD 1.002338
BTN 96.076978
BWP 14.120969
BYN 3.01672
BYR 19600
BZD 2.01597
CAD 1.42459
CDF 2310.000003
CHF 0.836205
CLF 0.024656
CLP 973.539878
CNY 6.70475
CNH 6.71436
COP 3314.79
CRC 457.846208
CUC 1
CUP 24.056893
CVE 97.29465
CZK 21.580966
DJF 178.497375
DKK 6.601103
DOP 59.602065
DZD 133.919964
EGP 51.941199
ERN 15
ETB 163.729916
EUR 0.88295
FJD 2.24875
FKP 0.756991
GBP 0.75445
GEL 2.60498
GGP 0.756991
GHS 11.732889
GIP 0.756991
GMD 74.000372
GNF 8750.000468
GTQ 7.658099
GYD 209.730789
HKD 7.84665
HNL 26.909604
HRK 6.6528
HTG 131.186306
HUF 323.419643
IDR 17937
ILS 3.07365
IMP 0.756991
INR 95.96915
IQD 1313.138889
IRR 1693792.502544
ISK 120.969796
JEP 0.756991
JMD 158.635902
JOD 0.708994
JPY 158.143502
KES 129.719972
KGS 87.4487
KHR 4065.101628
KMF 435.000056
KPW 900.000318
KRW 1360.175049
KWD 0.30903
KYD 0.835337
KZT 440.918897
LAK 22497.408184
LBP 89762.385847
LKR 331.231884
LRD 171.912363
LSL 16.416191
LTL 2.95274
LVL 0.60489
LYD 6.411082
MAD 9.723465
MDL 17.796797
MGA 4402.876428
MKD 54.331282
MMK 2099.600314
MNT 3599.1704
MOP 8.102072
MRU 40.144704
MUR 47.75987
MVR 15.449965
MWK 1738.121498
MXN 18.08776
MYR 4.086498
MZN 63.909596
NAD 16.41706
NGN 1326.860227
NIO 36.892099
NOK 9.633325
NPR 153.717739
NZD 1.77802
OMR 0.384505
PAB 1.002374
PEN 3.450819
PGK 4.536992
PHP 62.741981
PKR 277.681916
PLN 3.85205
PYG 5864.031411
QAR 3.65434
RON 4.657014
RSD 103.796978
RUB 83.375041
RWF 1480.037058
SAR 3.759293
SBD 8.032647
SCR 13.836223
SDG 601.505977
SEK 10.01845
SGD 1.27922
SHP 0.755829
SLE 24.649875
SLL 20969.491881
SOS 572.815106
SRD 37.621502
STD 20697.981008
STN 21.617329
SVC 8.77073
SYP 13002.000254
SZL 16.407994
THB 33.620498
TJS 9.232161
TMT 3.51
TND 2.97262
TOP 2.40776
TRY 49.032203
TTD 6.800164
TWD 31.937496
TZS 2640.002984
UAH 44.775489
UGX 3929.198542
UYU 40.386126
UZS 11858.028368
VES 857.98905
VND 25966
VUV 119.008285
WST 2.76852
XAF 579.17706
XAG 0.016353
XAU 0.000240041575
XCD 2.70255
XCG 1.806559
XDR 0.707052
XOF 579.17706
XPF 105.230186
YER 236.396786
ZAR 16.44243
ZMK 9001.20083
ZMW 19.596771
ZWL 321.999592
SSP 5712.591896
MXV 2.047495
  • RYCEF

    0.4000

    19.71

    +2.03%

  • CMSC

    0.0000

    20.4

    0%

  • BTI

    0.4200

    56.05

    +0.75%

  • BP

    0.2800

    44.43

    +0.63%

  • RBGPF

    1.6000

    67

    +2.39%

  • RIO

    -0.1500

    94.41

    -0.16%

  • AZN

    -0.4300

    166.15

    -0.26%

  • GSK

    0.4600

    49.7

    +0.93%

  • BCE

    -0.4100

    20.56

    -1.99%

  • NGG

    -0.2500

    75.24

    -0.33%

  • VOD

    -0.0400

    16.58

    -0.24%

  • RELX

    -0.4500

    33.07

    -1.36%

  • BCC

    -0.5500

    76.59

    -0.72%

  • CMSD

    -0.0300

    20.27

    -0.15%

  • JRI

    -0.2500

    10.77

    -2.32%

France's City of Light switches to climate-resilient power cables
France's City of Light switches to climate-resilient power cables / Photo: © AFP

France's City of Light switches to climate-resilient power cables

To maintain the glow of the City of Light, Paris is modernising its underground electric cables, vulnerable to damage during heatwaves and dating back 60 years.

Text size:

With power cables melting from Portland to Sicily, the world's 80 million kilometres (50 million miles) of power lines are largely unprepared to resist extreme temperatures, scientists have warned.

The French capital over the next few months will be replacing its obsolete paper-insulated lead-covered cables (PILC), which are made of oil-impregnated paper encased in a lead sheath.

"We're anticipating the renewal of these cables, which are starting to be affected by heat, to have a very resilient network in Paris," said Olivier Lagnel, deputy regional director for utility firm Enedis.

Nearby, workers in orange vests worked in a trench close to the Montparnasse train station to replace the medium voltage PILC, which were installed in 1965, with modern, plastic cables.

State-owned Enedis says Paris is not alone: its counterparts in Chicago, London, Shanghai, Hong Kong, Osaka, Tokyo, Singapore and Sydney also plan to update their cables.

- 'Climate emergency' -

Trouble has mounted in recent years.

Paper-insulated during a 2003 heatwave in France showed weaknesses with "an incident rate multiplied by eight across the medium-voltage underground network", according to a March 2024 report by France's Court of Audit.

Overhead tramway cables melted in Portland in 2021 during record-high temperatures in the northwest US state of Oregon.

A searing heatwave in July 2023 left hundreds of thousands of Sicilians without electricity and water for days.

Heat damage to underground cables was to blame, said supplier e-distribuzione, the distribution arm of energy giant Enel.

"We find ourselves operating in conditions of exceptional climatic emergency," where the temperature of the asphalt on roads reached 50 degrees Celsius (122 degrees Fahrenheit), it said in a statement at the time.

A 2021 study led by Alessandro Bosisio, an assistant professor at the University of Pavia in Italy, found that "an abnormal increase of faults in underground Medium Voltage cable joints has been recorded, especially during summer" worldwide in recent years.

Climate scientists say the period being lived through right now is likely the warmest the earth has seen for the last 100,000 years, back at the start of the last Ice Age.

- Avoid cuts -

PILC cables, which were the international standard from the late 19th century until the 1970s, were long considered highly reliable.

They were wrapped in layers of oily paper intended to isolate the centre of the cable, which heats up as electrons pass through.

The cables were conceived to resist temperatures up to 90C (194F). But when heat is trapped for days under the asphalt, they can reach 120-130C (248-266F) -- ageing faster and eventually risking failure.

Paris's 9,200 kilometres of low- and medium-voltage power cables are entirely buried underground -- to save space and protect them from the wind, Lagnel said.

Enedis plans to phase out the obsolete cables in French cities by 2050.

"The main problem is that the insulator can dry up, and in that case the cable can be sensitive," said Lagnel.

"The idea is to avoid cuts as much as possible" and to "desensitise the network... as heatwaves come back more and more often, stronger and stronger."

S.Davis--ThChM