The China Mail - France's City of Light switches to climate-resilient power cables

USD -
AED 3.673018
AFN 71.499636
ALL 87.061306
AMD 390.195672
ANG 1.80229
AOA 916.000034
ARS 1172.693095
AUD 1.55989
AWG 1.8025
AZN 1.699718
BAM 1.726572
BBD 2.025239
BDT 121.869938
BGN 1.728501
BHD 0.376935
BIF 2936
BMD 1
BND 1.310499
BOB 6.930829
BRL 5.715397
BSD 1.003041
BTN 84.76692
BWP 13.730882
BYN 3.282528
BYR 19600
BZD 2.014822
CAD 1.381835
CDF 2872.999859
CHF 0.827555
CLF 0.024698
CLP 947.759778
CNY 7.27135
CNH 7.25139
COP 4198.84
CRC 506.631944
CUC 1
CUP 26.5
CVE 97.341461
CZK 22.008496
DJF 177.720152
DKK 6.59382
DOP 59.032023
DZD 132.575928
EGP 50.791505
ERN 15
ETB 134.606849
EUR 0.88355
FJD 2.261504
FKP 0.749663
GBP 0.750985
GEL 2.744983
GGP 0.749663
GHS 14.293344
GIP 0.749663
GMD 71.497754
GNF 8687.515173
GTQ 7.724462
GYD 210.484964
HKD 7.75554
HNL 26.029114
HRK 6.662994
HTG 131.035244
HUF 357.020237
IDR 16452
ILS 3.62333
IMP 0.749663
INR 83.90985
IQD 1313.73847
IRR 42112.500395
ISK 128.749985
JEP 0.749663
JMD 158.78775
JOD 0.709204
JPY 145.184503
KES 129.349821
KGS 87.450048
KHR 4014.741906
KMF 434.501068
KPW 900.011381
KRW 1417.504978
KWD 0.30682
KYD 0.835783
KZT 514.647601
LAK 21686.066272
LBP 89872.479044
LKR 300.259103
LRD 200.606481
LSL 18.677031
LTL 2.95274
LVL 0.60489
LYD 5.475147
MAD 9.294287
MDL 17.217315
MGA 4453.70399
MKD 54.374964
MMK 2099.538189
MNT 3574.392419
MOP 8.012798
MRU 39.770298
MUR 45.520205
MVR 15.41012
MWK 1739.283964
MXN 19.56976
MYR 4.292504
MZN 63.999636
NAD 18.673816
NGN 1606.250077
NIO 36.90936
NOK 10.38069
NPR 135.627425
NZD 1.685857
OMR 0.384986
PAB 1.003032
PEN 3.677638
PGK 4.095253
PHP 55.593996
PKR 281.827034
PLN 3.78065
PYG 8033.511218
QAR 3.655833
RON 4.399198
RSD 103.446754
RUB 81.873197
RWF 1440.892679
SAR 3.750182
SBD 8.361298
SCR 14.652296
SDG 600.500744
SEK 9.70545
SGD 1.305403
SHP 0.785843
SLE 22.790523
SLL 20969.483762
SOS 573.196677
SRD 36.847032
STD 20697.981008
SVC 8.775321
SYP 13002.38052
SZL 18.660534
THB 33.143027
TJS 10.571919
TMT 3.5
TND 2.978994
TOP 2.342104
TRY 38.56613
TTD 6.792886
TWD 31.267501
TZS 2697.581986
UAH 41.609923
UGX 3674.195442
UYU 42.206459
UZS 12970.563573
VES 86.73797
VND 26005
VUV 120.584578
WST 2.773259
XAF 579.073422
XAG 0.030705
XAU 0.000307
XCD 2.702551
XDR 0.723012
XOF 579.08109
XPF 105.265016
YER 244.949563
ZAR 18.452455
ZMK 9001.191688
ZMW 27.90983
ZWL 321.999592
  • RBGPF

    67.2100

    67.21

    +100%

  • RIO

    -0.8500

    58.55

    -1.45%

  • RYCEF

    -0.1000

    10.12

    -0.99%

  • CMSC

    0.0200

    22.03

    +0.09%

  • SCS

    -0.0500

    9.87

    -0.51%

  • BP

    0.4200

    27.88

    +1.51%

  • BTI

    -0.2500

    43.3

    -0.58%

  • RELX

    -0.5500

    54.08

    -1.02%

  • GSK

    -1.1000

    38.75

    -2.84%

  • NGG

    -1.3500

    71.65

    -1.88%

  • VOD

    -0.0300

    9.73

    -0.31%

  • BCC

    -0.5700

    92.71

    -0.61%

  • CMSD

    -0.0400

    22.26

    -0.18%

  • JRI

    0.1000

    13.01

    +0.77%

  • BCE

    -0.8100

    21.44

    -3.78%

  • AZN

    -1.2800

    70.51

    -1.82%

France's City of Light switches to climate-resilient power cables
France's City of Light switches to climate-resilient power cables / Photo: © AFP

France's City of Light switches to climate-resilient power cables

To maintain the glow of the City of Light, Paris is modernising its underground electric cables, vulnerable to damage during heatwaves and dating back 60 years.

Text size:

With power cables melting from Portland to Sicily, the world's 80 million kilometres (50 million miles) of power lines are largely unprepared to resist extreme temperatures, scientists have warned.

The French capital over the next few months will be replacing its obsolete paper-insulated lead-covered cables (PILC), which are made of oil-impregnated paper encased in a lead sheath.

"We're anticipating the renewal of these cables, which are starting to be affected by heat, to have a very resilient network in Paris," said Olivier Lagnel, deputy regional director for utility firm Enedis.

Nearby, workers in orange vests worked in a trench close to the Montparnasse train station to replace the medium voltage PILC, which were installed in 1965, with modern, plastic cables.

State-owned Enedis says Paris is not alone: its counterparts in Chicago, London, Shanghai, Hong Kong, Osaka, Tokyo, Singapore and Sydney also plan to update their cables.

- 'Climate emergency' -

Trouble has mounted in recent years.

Paper-insulated during a 2003 heatwave in France showed weaknesses with "an incident rate multiplied by eight across the medium-voltage underground network", according to a March 2024 report by France's Court of Audit.

Overhead tramway cables melted in Portland in 2021 during record-high temperatures in the northwest US state of Oregon.

A searing heatwave in July 2023 left hundreds of thousands of Sicilians without electricity and water for days.

Heat damage to underground cables was to blame, said supplier e-distribuzione, the distribution arm of energy giant Enel.

"We find ourselves operating in conditions of exceptional climatic emergency," where the temperature of the asphalt on roads reached 50 degrees Celsius (122 degrees Fahrenheit), it said in a statement at the time.

A 2021 study led by Alessandro Bosisio, an assistant professor at the University of Pavia in Italy, found that "an abnormal increase of faults in underground Medium Voltage cable joints has been recorded, especially during summer" worldwide in recent years.

Climate scientists say the period being lived through right now is likely the warmest the earth has seen for the last 100,000 years, back at the start of the last Ice Age.

- Avoid cuts -

PILC cables, which were the international standard from the late 19th century until the 1970s, were long considered highly reliable.

They were wrapped in layers of oily paper intended to isolate the centre of the cable, which heats up as electrons pass through.

The cables were conceived to resist temperatures up to 90C (194F). But when heat is trapped for days under the asphalt, they can reach 120-130C (248-266F) -- ageing faster and eventually risking failure.

Paris's 9,200 kilometres of low- and medium-voltage power cables are entirely buried underground -- to save space and protect them from the wind, Lagnel said.

Enedis plans to phase out the obsolete cables in French cities by 2050.

"The main problem is that the insulator can dry up, and in that case the cable can be sensitive," said Lagnel.

"The idea is to avoid cuts as much as possible" and to "desensitise the network... as heatwaves come back more and more often, stronger and stronger."

S.Davis--ThChM