The China Mail - How Paris's Seine river keeps the Louvre cool in summer

USD -
AED 3.672498
AFN 66.489639
ALL 83.872087
AMD 382.479961
ANG 1.789982
AOA 916.999985
ARS 1450.743702
AUD 1.54464
AWG 1.8025
AZN 1.699936
BAM 1.69722
BBD 2.01352
BDT 122.007836
BGN 1.695365
BHD 0.376995
BIF 2949.338748
BMD 1
BND 1.304378
BOB 6.907594
BRL 5.359498
BSD 0.999679
BTN 88.558647
BWP 13.450775
BYN 3.407125
BYR 19600
BZD 2.010578
CAD 1.412195
CDF 2220.999879
CHF 0.806765
CLF 0.02406
CLP 943.870277
CNY 7.12675
CNH 7.121955
COP 3810.2
CRC 502.442792
CUC 1
CUP 26.5
CVE 95.686244
CZK 21.085038
DJF 177.719807
DKK 6.46671
DOP 64.320178
DZD 130.472159
EGP 47.297403
ERN 15
ETB 153.49263
EUR 0.86615
FJD 2.28525
FKP 0.766404
GBP 0.761505
GEL 2.71497
GGP 0.766404
GHS 10.92632
GIP 0.766404
GMD 73.509134
GNF 8677.881382
GTQ 7.6608
GYD 209.15339
HKD 7.77536
HNL 26.286056
HRK 6.525605
HTG 130.827172
HUF 334.42202
IDR 16704
ILS 3.272635
IMP 0.766404
INR 88.66155
IQD 1309.660176
IRR 42112.501708
ISK 126.640364
JEP 0.766404
JMD 160.35857
JOD 0.709002
JPY 152.931497
KES 129.149764
KGS 87.450218
KHR 4012.669762
KMF 427.999978
KPW 900.033283
KRW 1447.940003
KWD 0.30693
KYD 0.833167
KZT 526.13127
LAK 21717.265947
LBP 89523.367365
LKR 304.861328
LRD 182.946302
LSL 17.373217
LTL 2.95274
LVL 0.60489
LYD 5.466197
MAD 9.311066
MDL 17.114592
MGA 4508.159378
MKD 53.394772
MMK 2099.044592
MNT 3585.031206
MOP 8.005051
MRU 39.997917
MUR 45.999865
MVR 15.404993
MWK 1733.486063
MXN 18.621425
MYR 4.183006
MZN 63.960023
NAD 17.373217
NGN 1438.210482
NIO 36.78522
NOK 10.215903
NPR 141.693568
NZD 1.77559
OMR 0.384504
PAB 0.999779
PEN 3.375927
PGK 4.279045
PHP 58.9145
PKR 282.679805
PLN 3.68211
PYG 7081.988268
QAR 3.643566
RON 4.406497
RSD 101.52698
RUB 81.499636
RWF 1452.596867
SAR 3.750504
SBD 8.223823
SCR 14.35585
SDG 600.503157
SEK 9.57037
SGD 1.304195
SHP 0.750259
SLE 23.197576
SLL 20969.499529
SOS 571.349231
SRD 38.503505
STD 20697.981008
STN 21.260533
SVC 8.747304
SYP 11056.895466
SZL 17.359159
THB 32.393501
TJS 9.227278
TMT 3.5
TND 2.959939
TOP 2.342104
TRY 42.112499
TTD 6.773954
TWD 30.962802
TZS 2459.807029
UAH 42.066455
UGX 3491.096532
UYU 39.813947
UZS 11966.746503
VES 227.27225
VND 26315
VUV 122.169446
WST 2.82328
XAF 569.234174
XAG 0.020817
XAU 0.000251
XCD 2.70255
XCG 1.801686
XDR 0.70875
XOF 569.231704
XPF 103.489719
YER 238.495377
ZAR 17.383798
ZMK 9001.199567
ZMW 22.61803
ZWL 321.999592
  • BCC

    -0.6300

    70.75

    -0.89%

  • RYCEF

    0.0600

    15

    +0.4%

  • CMSC

    -0.0500

    23.78

    -0.21%

  • JRI

    -0.0200

    13.75

    -0.15%

  • VOD

    0.0700

    11.34

    +0.62%

  • NGG

    0.9400

    76.31

    +1.23%

  • SCS

    -0.1300

    15.8

    -0.82%

  • RIO

    0.2000

    69.26

    +0.29%

  • CMSD

    -0.0600

    23.95

    -0.25%

  • BCE

    0.7900

    23.18

    +3.41%

  • GSK

    0.4150

    47.105

    +0.88%

  • AZN

    2.6200

    83.77

    +3.13%

  • BTI

    0.3400

    54.22

    +0.63%

  • RELX

    -1.1900

    43.39

    -2.74%

  • BP

    0.1400

    35.82

    +0.39%

  • RBGPF

    0.0000

    76

    0%

How Paris's Seine river keeps the Louvre cool in summer
How Paris's Seine river keeps the Louvre cool in summer / Photo: © AFP

How Paris's Seine river keeps the Louvre cool in summer

As Paris braces for a heatwave this weekend, a little-known network of underground pipes will be cooling the Louvre museum and other storied landmarks using water from the Seine river.

Text size:

Since 1991, the river water has been cooling more than 800 buildings via a humble but hard-working system that is still relatively under-utilised worldwide.

Paris boasts the largest such urban cooling network in Europe: 110 kilometres (68 miles) of subterranean pipes criss-crossing the City of Light, reducing its need for energy-guzzling air conditioning.

"It's like 'Batman'!" exclaimed a passer-by in the chic and touristy eighth arrondissement or district of Paris, as a manhole cover was removed to reveal a spiral staircase to the cooling network below.

The technology is not new: the headquarters of the United Nations in New York has been using water from the East River for cooling since the 1950s.

But much planning and construction is necessary and as such, these efficient and sustainable cooling systems remain relatively rare.

But in Paris, the network has grown considerably in recent years to confront more intense and frequent heatwaves, with the first of the summer forecast this coming weekend.

The process works much the same as a district heating network, but in reverse: heat is transferred from the air to chilled water pumped via pipes to buildings around the city.

But unlike conventional air conditioning, it does not blast hot air into the streets, according to Fraicheur de Paris, which manages the Seine cooling network and others in Barcelona, Singapore and Dubai.

The company, co-owned by the French energy utility Engie, says it also offers significant savings in electricity consumption, chemical use and emissions of planet-warming carbon dioxide.

- Beat the heat -

Heatwaves could push summer temperatures to 50 degrees Celsius (122 Fahrenheit) by 2050 in Paris, said Raphaelle Nayral, secretary general of Fraicheur de Paris.

The city needs a more sustainable solution than air conditioning units with their associated heat and energy burden, she added.

"Otherwise we will make this city completely uninhabitable," Nayral said.

Studies have shown that air conditioners can increase the heat in urban centres by around 0.5C when used in large numbers, a figure that rises as more units are installed.

Air conditioning also accounts for seven percent of global greenhouse gas emissions, the UN estimates. This is in part due to energy use but also leaking refrigerant gases, which are potent warming agents.

For the Paris network, 12 cooling power stations pump chilled water from the Seine to 867 sites across the city, including the national parliament building.

Even in winter, the river can prove useful for cooling server rooms and other technology and heat-intensive operations across the city.

- 'Song of the Seine' -

In the eighth district, 30 metres underground and spread over four floors, the river's water is pumped through a series of black tanks and large green pipes with a shrill din.

"It's a bit like the song of the Seine," Raynal said with a smile over the whirring of compressors.

The process is subject to numerous environmental standards.

To prevent damage to the Seine ecosystem, water drawn for cooling cannot be discharged back into the river if there is a difference of more than 5C (9F) between the two.

Other sites served by the Paris network include department stores and offices, the train network, concert halls, and arguably the world's most famous museum, the Louvre.

One hospital has been also connected, and there are hopes of extending the cooling benefit to retirement homes, schools and daycare centres across the city.

"By 2042, the network should more than double, with 245 kilometres of distribution... to provide new cooling when the city is overheating," Nayral said.

For individual homes, it could be a longer wait, with extensive renovations required to connect residential buildings to the network.

X.So--ThChM